Cantilever retaining wall
The inverted-T wall: a stem on a base with a toe in front and a heel under the retained soil.
Earth-retaining & foundations
Enter the wall, see the section and the checks update as you type, then let the tool search thousands of proportions for the ones with the least steel, concrete and cost. Every number comes with its formula, the values put into it and the IS clause.
Sample wall 4.0 m high, flat backfill, seismic zone III, per metre run. Overturning factor of safety 2.20 (required 1.5). Sliding 1.42 (required 1.4). Maximum base pressure 120 kN/m² against 200 kN/m² allowed. Stem steel 12 mm bars at 140 mm. Concrete 2.18 m³ and steel 74 kg per metre run.
Drag the drawing up or down, or use the slider. A sample wall per metre run, flat backfill, seismic zone III: the proportions, bars and checks are the engine's.
How it works
The method for a cantilever wall is settled in the codes. What takes the day is redoing it: every change to the height, the soil or the water table means the stability, the reinforcement, the crack width and the drawing are worked again. The tool does that pass in seconds.
Give the wall height. The toe, heel and thicknesses are proportioned and then refined until the section works.
Backfill, water table and surcharge sit behind the stem. Ground levels front and back are set.
Rankine active pressure builds to a maximum at the base. Its resultant is what the wall must resist.
Stem, toe and heel are designed as slab strips: bar size, spacing, shear and development length.
Dimensions, bar marks and a bending schedule complete the drawing, ready to download.
Earthquake case
Switch on the earthquake case and pick the zone: the tool adds the Mononobe-Okabe increment of IS 1893 Part 3 and checks stability with the earthquake factors of safety. A 5 m wall, across the zones.
Options
The same wall, optimised three ways. Every option passes every check.
The tool searches thousands of proportions with every standard bar size from 8 to 32 mm, keeps the walls that pass every check, and picks the three options from them.
The working
The formula, the values put into it, the result and the code clause: the same working a checker would write by hand.
Outputs
These samples are clean copies. During the 14-day free trial your own report and drawing carry a "TRIAL - NOT FOR CONSTRUCTION" watermark; a subscription removes it.
The inverted-T wall: a stem on a base with a toe in front and a heel under the retained soil.
A cantilever wall with no toe: the stem stands at the front edge of the base.
No heel: the back of the stem is the back edge of the base, with a long toe and usually a shear key.
A wall propped near the top by a slab or strut, for taller walls and basements.
IS 456 for the concrete design, IS 1893 (Parts 1 and 3) for the earthquake case, IS 14458 for retaining walls, IS 6403 and IS 1904 for the foundation, IS 875 for loads, IS 1786 for the steel and IS 2502 for the bar bending schedule. Every result cites its clause.
Yes. Each step shows the formula, the values put into it, the result and the clause, in the app, in the PDF report and in the member calculation files.
An A3 DXF sheet with the section and plan to a scale chosen by the wall size, the bar bending schedule, general notes and a title block. AutoCAD and most CAD programs open DXF.
Yes. Switch on the earthquake case and choose the seismic zone (there is no default zone). The tool adds the Mononobe-Okabe increment of IS 1893 Part 3 and checks overturning, sliding and bearing with the earthquake factors of safety.
Yes. The soil friction angle, factors of safety, exposure, cover and cost rates are inputs, and every assumption that is not a code clause is listed in the report.
Sign up, no card, and every feature is yours for 14 days: your own walls, the search, options A, B and C and every calculation. Reports and drawings carry a TRIAL - NOT FOR CONSTRUCTION watermark. Before signing up you can open the example wall and read its full working.
No. It does the calculation and the drafting; the engineer reviews the design and remains responsible for it.
Isolated and combined RCC footings to IS 456: size from bearing, then flexure, one-way and punching shear, and the drawing.
Rectangular and circular RCC water tanks to IS 3370:2021, designed for watertightness (w <= 0.10 mm) as well as strength.
A submission-ready Design Basis Report (DBR) for low- and high-rise buildings: codes, materials, loads, seismic and wind data, combinations and limits.
Start a 14-day free trial, no card needed, or open the example wall first.