Retaining walls
Design RCC retaining walls to IS 456 and IS 1893: stability, member design, crack width, a calculation report, bar bending schedule and drawing.
Indian Standard · 2000
Plain and Reinforced Concrete — Code of Practice. The general code for concrete design in India: materials, durability, limit state design for flexure, shear, torsion and compression, serviceability, and detailing.
The clauses its calculation cites, step by step, taken from the tool's own worked example.
| Clause | Used for |
|---|---|
| cl. 20.1 | Overturning about the toe |
| cl. 20.2 | Sliding along the base |
| Table 18 (cl. 36.4) | Design (factored) moment; Design (factored) shear |
| cl. 26.4, 26.4.2.2 | Effective depth (1 m wide strip) |
| cl. 38.1, Annex G | Limiting moment of resistance |
| cl. 38.1 | Singly reinforced section check |
| Annex G, cl. G-1.1(b) | Tension steel for flexure |
| cl. 26.5.2.1 | Minimum tension steel; Steel provided |
| cl. 26.5.2.1, Annex G | Steel required |
| cl. 26.3.3(b) | Bar diameter and spacing |
| cl. 40.1 | Nominal shear stress |
| Table 19, cl. 40.2.1.1 | Permissible shear stress without stirrups |
| cl. 40.2.1 | Shear check |
| cl. 26.2.1.1 | Development length of main bars |
| cl. 26.5.2.1, 26.3.3(b) | Distribution (secondary) steel |
| Annex F (cl. 35.3.2) | Surface crack width under service moment |
| cl. 35.3.2 | Crack width check |
| cl. 26.2.3 | Curtailment of the main bars |
| cl. 20 | Base pressure |
Design RCC retaining walls to IS 456 and IS 1893: stability, member design, crack width, a calculation report, bar bending schedule and drawing.
Isolated and combined RCC footings to IS 456: size from bearing, then flexure, one-way and punching shear, and the drawing.
Rectangular and circular RCC water tanks to IS 3370:2021, designed for watertightness (w <= 0.10 mm) as well as strength.
A submission-ready Design Basis Report (DBR) for low- and high-rise buildings: codes, materials, loads, seismic and wind data, combinations and limits.
Wind loads on buildings to IS 875 Part 3: wind speed and pressure, pressure coefficients, storey forces, the gust factor and IS 16700 tall-building checks.
Deflection checks for beams and slabs to IS 456: the span-to-depth route and a calculated deflection, side by side.
RCC staircases to IS 456: dog-legged and open-well flights, waist slab design and detailing.
One-way and two-way RCC slabs to IS 456, with the moment coefficients for the edge conditions.
RCC columns to IS 456: axial load with uniaxial and biaxial bending, slenderness and ties.
Start a 14-day free trial, no card needed, or open the example wall first.